IndustriesPlumbing, heating, ventilation

Pipework, heat load and riser diagram from one model.

Pipes hang on ports and move with them. Heat load, radiators, balancing, drinking water and drainage are worked out on the building model and put their record on a sheet.

For contractors who plan what they build, such as a heat pump in an existing house or a new bathroom, and for small building services offices.

H02Heating pipework, ground floorM 1:50A1

Sheets from the example projects, plotted with Linework. A click opens the whole sheet.

Heating

  • Heat load by room

    From the building model, following the method of EN 12831-1: walls with what lies behind them, windows, roof, ground, ventilation. U-values come from the layers.

    heatloadclimate
  • Radiators and underfloor heating

    Linework checks radiators at your flow and return temperatures against the heat load and proposes the standard output needed. Underfloor heating is laid per room and worked through for output, surface temperature and pressure drop.

    radiatorcheckfloorheatingfloorcheck
  • Hydraulic balancing

    Flow per radiator, pressure drop in the network, valve presetting from the maker’s table, the pump. With it the record of the calculation and a confirmation to sign.

    balance
HHeat load by room, preliminary sizing–A4

Drinking water and drainage

  • Drinking water

    Peak flow, velocity, friction and pressure demand per flow path, following the method of DIN 1988-300. Circulation works out heat loss, the pump and balancing valves.

    drinkingwatercirculationhygienecheck
  • Drainage

    Discharge units per pipe, horizontal pipes partly filled, stacks against their capacity, following the method of EN 12056-2. You draw pipes with their fall straight away.

    drainageconnect
  • Ventilation concept

    Whether a ventilation measure is needed and how much air per room, following the method of DIN 1946-6. You draw ducts as connections with duct sizes.

    ventconcept
S02Plumbing, ground floorM 1:50A1

Drawings and material

  • Pipe plan, riser diagram, isometric

    The pipe plan shows double lines with insulation, hidden parts dashed. The riser diagram comes from the network, across storeys at true heights too, the isometric at 30°.

    pipeplannetdiagramnetiso
  • Fittings and bill of materials

    Bends, tees and reducers become objects. The bill of materials counts metres per system and type, fittings, insulation and weights, as a table or CSV.

    fittingspipelistinsulate
  • Chases and openings

    Openings from pipe and duct sizes, numbered, with a list, for the architect to approve or reject.

    provisions
S04Drinking water riser diagram, waste water isometric–A2

Formats

In

IFC 2x3 / 4DWG, DXF, PDFCSV

Out

PDF, PDF/AIFC 4CSVBCF

All formats and what they carry

Symbol packs

  • Plumbing installation: 8 symbols with ports for cold, hot and waste water, plus radiators and heating manifolds as parts.
  • Valves and appliances: 24 symbols for valves, pump, heat generators, cylinders and ventilation.

Packs are content, not program. They come with the download, and you install them in the app. Any DWG with your own blocks becomes a library the same way.

What is still missing

  • Every result is a preliminary sizing and says so in its title. Verification remains with the planner.
  • Tables from standards are not included. You supply room temperatures, climate data, design flows and coefficients; the pipe catalogue comes empty too.
  • Ventilation ducts are drawn and counted in the bill of materials; the duct network is not calculated.
  • Makers’ data, wholesalers’ article numbers and heat pump sizing are missing.

In the examples

Download Linework and open one of your drawings.

The app is free, for professional work too, without an account or a licence key.

Product
FrameMind Linework
Version
0.19.2
Date
13 November 2026
Platform
macOS, Apple silicon
Windows
in preparation
Price
free

The wheel zooms, dragging pans, a double click shows everything.